Description
■ Pure sine wave output
■ Built-in 50A PWM solar charge controller
■ Smart LCD setting ( frequency , charge voltage, charge current, etc).
■ Overload and short-circuit protection
■ Deep discharge protection
■ Cold start function
■ Support USB/RS232 monitoring function
MODEL | PV20-1012 PK | PV20-1512 PK | PV20-2024 PK |
Battery Input Voltage Rating | 12VDC | 24VDC | |
INVERTER OUTPUT | |||
Rated Power | 1000VA/700W | 1500VA/900W | 2000VA/1200W |
Instantaneous Power Drawn | 2100VA | 2700VA | 3600VA |
Output Waveform | Pure sine wave | ||
Output Voltage | Inverter mode: 230VAC(±5% RMS), AVR mode: 200VAC-240VAC 220VAC(±5% RMS) | ||
Output Power Factor | 0.7 | 0.6 | |
Output Frequency | 50Hz/60Hz ±0.2 Hz | ||
Inverting Efficiency (peak) | >85% | ||
Mains Mode Efficiency | > 95% | ||
Transfer Time | Typical 2~6ms 10ms(max) | ||
AC INPUT | |||
Input Voltage | 220/230VAC | ||
Input Voltage Range | 140~280VAC±5% | ||
Low Pressure Shutdown | 140VAC±5% | ||
High Pressure Shutdown | 280VAC±5% | ||
Low Frequency Shutdown | 45±0.2Hz(50Hz) | ||
High Frequency Shutdown | 65±0.2Hz(60Hz) | ||
Frequency Range | 50Hz/60Hz ±0.2HZ | ||
BATTERY | |||
Minimum Start Voltage | Battery under voltage shut-down point +0.5V | Battery under voltage shut-down point +1.0V | |
Low Battery Alarm | Battery under voltage shut-down point +0.5V | Battery under voltage shut-down point +1.0V | |
Low Battery Shutdown | (0.1V / 10-12.0VDC mode) User set | (0.2V / 20.0-24.0VDC mode) User set | |
Battery High Voltage Alarm | Average Charge Voltage+1V | Average Charge Voltage +2V | |
AC CHARGER | |||
Float Voltage | 13.5~14.5VDC to set | 27~29VDC to set | |
Average Charge Voltage | (0.1V each click ,13.8~14.5V mode) User set | (0.2V each click , 27.6~29V mode) User set | |
Maximum Charge Current | 20A±2A | 25A±2A | 15A±2A |
BYPASS & PROTECTION | |||
Input Frequency | 50Hz / 60Hz | ||
Low Frequency Switching | 45±1Hz | ||
High Frequency Switching | 65±1Hz | ||
Overload Protection | 110%~125%R load fault after 60s 125% ~150%R load fault after 3s >150%R load fault after 500ms | ||
Output Short Circuit Protection | Yes | ||
Bypass Circuit Breaker Insurance | 10A | ||
Maximum Current Bypass | 10A | 10A | |
SOLAR CHARGER | |||
Maximum PV Charge Current | 50A±5A | ||
Battery Voltage | 12VDC | 24VDC | |
Maximum PV Array Power | 150W*5 solar panels | 150W*10 solar panels | |
Maximum PV Array Open Circuit Voltage | 55Vdc | ||
Maximum Efficiency | > 95% | ||
Standby Consumption | <2W | ||
MECHANICAL SPECIFICATIONS | |||
Assembly | Wall mount | ||
Machine Dimension (W*H*D) | 300.5*319*132.2mm | ||
Package Dimension (W*H*D) | 391*325*187mm | ||
N.W (kg) | / | ||
G.W (kg) | / | ||
OTHER | |||
Working Environment | 0°C~40°C 0~90% Relative humidity (non-condensing) | ||
Noise | Less than 60db | ||
Display | LED + LCD | ||
CERTIFICATION & STANDARDS | |||
CE-EMC+LVD(EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011) |