PV1500 LV Series (AC:120V 1500VA)

Off Grid Solar Inverter 1500VA | AC 120V | PV 100V

It is a cost efective, inteligent solar inverter which accepts Solar & Utility input at the same fime. The comprehensive lCD display ofers user-conigurable and easy-accessible buton adjustment such as batery charging curent, AC/solar charger priority and DC priority,.When battery voltage islow,it will automatically switch to AC grid to supply continuous power to the loads.

Description

Description

■ Built-in 30A MPPT Solar Charge Controller

■ 10A or 15A standard charging current from utility AC

■ 2 Output ports for DC load

■ AC/solar priority for charging via MFD

■ Different charging mode for different kinds of batteries

■ Overload & short-circuit protection, Battery reverse polarity protection, Deep discharge protection

■ Auto restart while AC/solar is recovering Adjustable solar and utilitycharging current

■ Support fast max charging current setting

■ Support two kinds of batteries: LiFePO4 Lithium Battery Packand Lead-acid Battery

■ Automatic activate lithium battery pack which is be over discharged no output when AC input is OK

MODEL PV15-0612 LV PV15-1012 LV PV15-1524 LV
Nominal Battery System Voltage 12VDC 12VDC 24VDC
NVERTER OUTPUT
Rated Power 600VA / 600W 1000VA / 1000W 1500VA / 1500W
Waveform Pure Sine Wave
Nominal Output Voltage RMS 120VAC
Output Voltage Regulation +10/-18%
Output Frequency 50Hz / 60Hz ± 1Hz
Inverter Efficiency (Peak) >90%
Line Mode Efficiency >95%
Typical Transfer Time Typical 10ms(UPS,UL) , Typical 20ms(APL,DEF)
AC INPUT
Voltage 120VAC
Voltage Range 74 ~ 145VAC ± 3%
Frequency Range 40 ~ 65Hz ± 2Hz
BATTERY
Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack – 12V(4 Series) 24V(8 Series)
Nominal Input Voltage 12VDC 24VDC
Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)
Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
High Battery Voltage Recover 14.5VDC(PB) 14.5VDC(LI) 29.0VDC(PB) 29.0VDC(LI)
High Battery Voltage Cutoff 15.0VDC(PB) 15.0VDC(LI) 30.0VDC(PB) 30.0VDC(LI)
Charger Voltage boost 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)
Charger Voltage float 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)
SOLAR CHARGER & AC CHARGER
Maximum PV Charge Current 40A (max)
Maximum PV Array Power 600W 1200W
MPPT Operating Voltage Range 15 ~ 75VDC 30 ~ 75VDC
Maximum PV Array Open Voltage 105VDC
Maximum Efficiency > 95%
AC Charging Current Max 40A (Can be set) 20A (Can be set)
Maximum Charge Current AC+PV 80A (Can be set) 60A (Can be set)
BYPASS & PROTECTION
Output Short Circuit Protection FUSE
Bypass breaker Rating 15A 20A 30A
Max Bypass Current 15A 20A 30A
Battery Fuse Current 50A * 2 50A * 3 40A * 3
DIMENSIONS
Machine Dimension (W*H*D)(mm) 320*264.5*95
Package Dimension (W*H*D)(mm) 390*335*167
N.W(kg) 4.5 4.7
G.W(kg) 5.4 5.6
OTHER
Operating Temperature Range 0°C to 45°C
Audible Noise 50dB MAX
Display LED+LCD
Standard Warranty 2 year